Thesis Open Access
Kassu Bekele
<?xml version='1.0' encoding='utf-8'?> <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"> <dc:creator>Kassu Bekele</dc:creator> <dc:date>2017-07-01</dc:date> <dc:description>The transmission line in an electrified railway system must provide power transmission within the voltage limit at safe and quality conditions. Therefore, system analysis within the traction power system is vital to the design and operation of an electrified railway. Loads in traction power system are often characterized by their mobility, wide range of power variations, regeneration and service dependence. One of the main problems in the railway supply stations are the voltage drops due to the changes of the load. Voltage drop in electrified railway have an influence on the location of traction substation (reduces distance between traction transformer and section post length) and operating railway transport in a such condition disturbs transportation system, as a result the reactive power compensator should be installed to have a better voltage at receiving end. Ethiopian railway cooperation is constructing national railway transport from Sebeta to Meiso with seven feeding traction substation from Sebeta to Adama. In this thesis traction network voltage drop analysis is undertaken for various feeding condition. Taking sample section from Sebeta substation to Indode substation analyses of the traction network voltage drop over the feeding condition has been conducted for different loading cases. The modeling and simulation of the system is done by MATLAB/SIMULINK software</dc:description> <dc:identifier>https://zenodo.org/record/4190</dc:identifier> <dc:identifier>10.20372/nadre:4190</dc:identifier> <dc:identifier>oai:zenodo.org:4190</dc:identifier> <dc:relation>doi:10.20372/nadre:4189</dc:relation> <dc:relation>url:https://nadre.ethernet.edu.et/communities/aau</dc:relation> <dc:relation>url:https://nadre.ethernet.edu.et/communities/zenodo</dc:relation> <dc:rights>info:eu-repo/semantics/openAccess</dc:rights> <dc:rights>http://www.opendefinition.org/licenses/cc-by</dc:rights> <dc:title>Assessment and Mitigation of Voltage Drops on Traction Lines: Case Study of Sebeta-Adama Line</dc:title> <dc:type>info:eu-repo/semantics/doctoralThesis</dc:type> <dc:type>publication-thesis</dc:type> </oai_dc:dc>
All versions | This version | |
---|---|---|
Views | 0 | 0 |
Downloads | 0 | 0 |
Data volume | 0 Bytes | 0 Bytes |
Unique views | 0 | 0 |
Unique downloads | 0 | 0 |